Avaliação (em escala laboratorial) da aplicação do processo eletrolítico em efluente de lagoa de estabilização de esgoto urbano.

Informe múltiplos e-mails separados por vírgula.

imagem

Autoria: CLARO, E. M. T.; OTENIO, M. H.; BIDÓIA, E. D.; SILVA, N. M. M. G.; SANTOS, V. dos

Resumo: Physico-chemical and microbiological parameters were evaluated before and after applying an electrolytic process to effluents of a stabilization lagoon, in the presence or absence of ?salt?. Chlorine generation and bactericidal properties of the treatments were studied following two experiments. Effluent pH increased with electrolysis time. In the absence of ?salt?, 20 min electrolysis resulted in a COD (Chemical Oxygen Demand) reduction of 44%, along with ca. 99.9% (3 log10 cfu/mL) reduction in total coliforms, heterotrophic bacteria and Escherichia coli. These results indicated that the electrolytic process is a promising complementary technology to improve effluent quality for stabilization lagoons.

Ano de publicação: 2010

Tipo de publicação: Artigo de periódico

Observações

1 - Por padrão são exibidas publicações dos últimos 20 anos. Para encontrar publicações mais antigas, configure o filtro ano de publicação, colocando o ano a partir do qual você deseja encontrar publicações. O filtro está na coluna da esquerda na busca acima. 

2 - Para ler algumas publicações da Embrapa (apenas as que estão em formato ePub), é necessário ter, no celular ou computador, um desses softwares gratuitos. Sistemas Android: Google Play Livros; IOS: iBooks; Windows e Linux: software Calibre.

 


Acesse outras publicações