Avaliação (em escala laboratorial) da aplicação do processo eletrolítico em efluente de lagoa de estabilização de esgoto urbano.
Avaliação (em escala laboratorial) da aplicação do processo eletrolítico em efluente de lagoa de estabilização de esgoto urbano.
Author(s): CLARO, E. M. T.; OTENIO, M. H.; BIDÓIA, E. D.; SILVA, N. M. M. G.; SANTOS, V. dos
Summary: Physico-chemical and microbiological parameters were evaluated before and after applying an electrolytic process to effluents of a stabilization lagoon, in the presence or absence of ?salt?. Chlorine generation and bactericidal properties of the treatments were studied following two experiments. Effluent pH increased with electrolysis time. In the absence of ?salt?, 20 min electrolysis resulted in a COD (Chemical Oxygen Demand) reduction of 44%, along with ca. 99.9% (3 log10 cfu/mL) reduction in total coliforms, heterotrophic bacteria and Escherichia coli. These results indicated that the electrolytic process is a promising complementary technology to improve effluent quality for stabilization lagoons.
Publication year: 2010
Types of publication: Journal article
Unit: Embrapa Dairy Cattle
Keywords: Desinfecção, Eletrólise, Tratamento de efluentes
Observation
Some of Embrapa's publications are published as ePub files. To read them, use or download one of the following free software options to your computer or mobile device. Android: Google Play Books; IOS: iBooks; Windows and Linux: Calibre.